2 Years
Type:
Alternating Pressure
Type:
True Low Air Loss
Size:
36" x 80"
Height:
10"
Features:
Power Out Feature
Features:
Pulse Therapy
Features:
Antimicrobial
Airflow Rate:
1300 LPM
Classification:
Group 2
Classification:
Pressure Relief Air Mattress
Classification:
Bariatric
Weight Capacity:
550 lbs

Order Cancellations

Because NewLeaf strives to deliver customer orders as quickly as possible, most orders are processed and shipped the day they are ordered. Orders that are cancelled after they have shipped are subject to any applicable manufacturer restocking fees, return shipping and original shipping costs as outlined below.

Orders that have been paid for by credit card, debit card, or PayPal may be subject to the non-recoverable 3.5% processing fee that is assessed by the credit card company when a transaction is processed.

Returns & Exchange Policy

Your satisfaction as our customer is our top priority, and we want you to be completely satisified with your purchase. Because many of the items offered at NewLeaf Home Medical are considered "Medical Devices," there are a few strict guidelines that need to be followed for medical compliance and hygenic reasons.

Non-Returnable Items

There are certain products that are inherently Non-Returnable due to the nature of the product, sterile/hygienic concerns, or for custom-built reasons. The following products if the product has been put into use: Mattresses; Mattress Pads; Bath Lifts; Bathroom Safety Products; Bedding Products. Items NOT eligible for return if the product packaging has been opened include, but are not limited to: Products classified as a "Medical Device" by the manufacturer or the FDA (Food & Drug Administration); Case Pack items; Contour Products (pillows, body positioners, etc.); and MOXI and Prius Mattress products. Mattress or Bathroom products that have been put into use are NOT eligible for return. Custom or Made-to-Order items NOT eligible for return include, but are not limited to: Recliners from Winco, Lumex, and some Pride Lift Chairs; Beds from Big Boyz Beds, Dawn House, Dynarex, Flexabed, Med-Mizer, and Transfer Master; and Mattresses from *Flexabed, Med-Mizer, Moxi Mattresses, and Transfer Master. Recliners are Non-Returneable if they have been unboxed and/or assembled, which includes but is not limited to: Drive Medical, Dynarex, Invacare, Lumex (Made-to-Order models are not returnable under any circumstances), Pride (Made-to-Order models are not returnable under any circumstances), and Winco (Made-to-Order models are not returnable under any circumstances). Patient Lift products are Non-Returneable, which include, but are not limited to: BestCare, Drive Medical, Invacare, Traxx Mobility, Protekt, and Lumex. *Flexabed mattresses may be exchanged for another mattress type within 30 days. Shipping fees an packing costs will apply. Mattresses must be returned in New condition.

Restocking & Shipping Fees

The standard restocking fee for many, but not all, items sold at NewLeaf Home Medical is 20%. However, the following supplier-sourced items are subject to restocking fees that are dictated by the manufacturer: Contour Products *Non-Returnable if product packaging has been opened, otherwise (25%); Drive Medical (25%); Dynarex (20%); Flexabed (20%); Lumex/Graham Field (25%); Invacare (25%); Pride Lift Chairs (25%); Prius (20%); Protekt Mattresses (25%); Rhythm Healthcare *20 Day return policy (20%); and Traxx Mobility (25%).

While many of our products are offered with "Free Shipping," the actual incurred ship-to costs cannot be recouped from the shipping company once your item has shipped. As a result, this cost will be deducted from your eligible return refund. Original shipping costs may be waived if exchanging for another item of same or greater value.

Orders that were paid for by credit card, debit card, or PayPal may be subject to a non-recoverable 3.5% processing fee that was assessed by the payment processor when your transaction was processed.

Return Shipping

Return shipping costs are the responsibility of the customer unless the return item(s) was damaged during shipment to you, the item you received was not what you ordered, or the return is due to a warranty issue.

Return Timeframe & Requirements

You have 30 calendar days to return an item from the date you received your order *If your item is not classified as a "Non-Returnable" item, or the manufacturer stipulates a different return window period. If you need additional details or have questions about a product before placing your order, or if you would like to return or exchange your purchase, please contact our Customer Care Team at 888.739.4330. It is IMPORTANT to note that:

Items must be returned in New, Unused and Resalable Condition.

Return items must be shipped back in the original shipping carton with manufacturer retail packaging. *Manufacturers will not grant return authorization if the original box and packaging has been discarded because the retail packaging is necessary to be able to resell the merchandise as "New."

Medical devices like Feeding Tubes, Catheters, Oxygen Tubing/Masks, Bathroom, Bedding or Mattress products, and other items with "hygienic" classifications are only eligible for return if the item packaging is unopened and unused.

How Do You Request a Return?

Please see Return Instructions by this link to the Returns, Cancellations & Exchange Policy page.

Harmony True Low Air Loss Tri-Therapy Mattress System, 36" x 80"

MSRP: $4,568.90
NewLeaf Price: $2,437.50
(You save $2,131.40 )
Brand
Item#:
14200N
UPC:
14000N
MSRP: $4,568.90
NewLeaf Price: $2,437.50
(You save $2,131.40 )
Adding to cart… The item has been added

Description

The Drive Harmony Mattress 14000N is a True Low Air Loss, Tri-Therapy active high-flow system that aids in the prevention and treatment of pressure injuries. The Harmony provides micro-climate control, pulsation, and alternating pressure therapies to optimize patient comfort and pressure redistribution. The removable, quilted four way stretch polyurethane coated cover is manufactured with an antimicrobial* agent and is fluid resistant, low shear and vapor permeable helping protect the skin from friction and moisture. With 20 individual, 8” deep air cells this system provides optimal patient comfort and pressure redistribution. Featuring a 2” foam base offers protection in the event of a power outage or system failure. Able to accommodate patients up to 550 lbs, and available in 36"W x 80"L x 10"H.

*PerserveTech provides antimicrobial properties that  are built in to protect the products. These products do not protect users or others against bacteria, viruses, germs, or other disease organisms. EPA registration 92760-9 is Ultra-Fresh DW-30, which is registered to control the growth of fungi, bacteria and algae in polyurethane foams, rubber, non-aqueous coatings, adhesives, PVC and grout mortar and mastics.

Features

  • 4 Therapy Cycle Times ranging from 5 to 20 minutes
  • 10 Adjustable Weight Settings for optimal immersion and patient satisfaction
  • True Low Air Loss wicks away moisture and humidity providing micro-climate control to keep patient cool and dry
  • Audio/Visual Alarms in the event of power outage, low pressure (hose disconnect), and alternating failure
  • 20 individual, 8” deep air cells provide optimal patient comfort and pressure redistribution
  • Blower provides 1300 LPM (liters per minute" of air flow. Sound level is approximately 50 dB at its peak
  • Power Outage Feature, 2” foam base offers protection in the event of a power outage or system failure
  • Auto Firm Feature inflates air cells in under two minutes for rapid set up and caregiving procedure
  • Anti-microbial Quilted Four Way Stretch Cover is fluid resistant, low shear and vapor permeable helping protect the skin from friction and moisture
  • Built in Cable Management with (5) side mattress loops to keep cables off the floor, reducing tripping hazards
  • Carry Bag allows the system to be compactly wrapped for quick and easy storage 
  • CPR Connector in case of emergency procedures releases the air immediately from the mattress for rapid deflation.
  • Pulsation Therapy to help stimulate and promote capillary blood flow to the skin
  • Seat-Inflate increases air flow by 20% to middle bladders to prevent bottoming out
  • Static Mode temporarily turns off alternating pressure therapy

Specification

Airflow 1,300 LPM
Cycle Time 5, 10, 15, 20 minutes
Pump Type High Flow Digital Blower
Pump Sound Level 50 dB
Alarms

Low Pressure, Power Failure, System Failure

Mattress Widths

36"W

Mattress Length 80"L
Mattress Depth 10"H (8" air cells + 2" foam base)
Mattress Cover Material Fluid-Resistant, 4-way Stretch
Weight Capacity 550 lbs
Pump Power 120/60Hz
Warranty 2 Years